Deye Inverter 20KVA – 3 Phase Low Voltage

$3,200.00
In Stock

This product has been added to 6041 people'scarts.

In Stock
SKU: DEYE20KVA3LV
Tags: ,
Brand:

Description

The Deye Inverter 20KVA – 3 phase Low voltage is a reliable power solution designed to meet your energy backup needs with efficiency and performance. This inverter offers a seamless transition during power outages, ensuring a continuous power supply for your home or business.

Modell SUN-20K-SG05LP3
-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 350
Max. Discharging Current (A) 350
Charging Strategy forLi-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 40000
Max. DC Input Power (W) 32000
Max. DC Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 160-650
Rated DC Input Voltage (V) 550
Max. Operating PV Input Current (A) 36+20
Max. Input Short-Circuit Current (A) 54+30
No.of MPPT Trackers/ 2/2+1
No.of String PerMPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 20000
Max. AC Input/Output Apparent Power (VA) 22000
Rated AC Input/Output Current (A) 30.4/29
Max. AC Input/Output Current (A) 33.4/31.9
Max. Continuous AC Passthrough (grid to load) (A) 70
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V  0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Component of Grid <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPTEfficiency >99%
Equipment Protection
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise ≤60
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 456×750×268.5 (Excluding Connectors and Brackets)
Weight (kg) 50.6
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2